BRKKH - BATTERY STORAGE,NI-CAD

Product Identification

Product ID:BATTERY STORAGE,NI-CAD
MSDS Date:10/21/1986
FSC:6140
NIIN:01-142-8488
MSDS Number: BRKKH

Responsible Party
SAFT AMERICA INC., POWER SOURCES DIV.
711 INDUSTRIAL BLVD
VALDOSTA, GA 31603
US

Emergency Phone: 912-247-2331

Info Phone: 912-247-2331

Preparer: DGSC-SSH

Cage: 09052

Contractor
SAFT AMERICA INC.
1886 VALDOSTA, GA 31602 US

Telephone: 912-247-2331

Cage: 09052

Ingredients

POTASSIUM HYDROXIDE (SARA III)

CAS: 1310-58-3

RTECS: TT2100000

OSHA PEL C, 2 MG/M3

ACGIH TLV: C 2 MG/M3; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CADMIUM (SARA III)

CAS: 7440-43-9

RTECS: EU9800000

OSHA PEL SEE 1910.1027

ACGIH TLV: 0.01 MG/M3 DUST;9394

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


NICKEL (SARA III)

CAS: 7440-02-0

RTECS: QR5950000

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9192


NON-HAZARDOUS INGREDIENTS

Hazards

LD50 LC50 Mixture:NOT KNOWN
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:NONE. IF BATTERY IS BROKEN OR LEAKING,
ELECTROLYTE (LIQUID) IS CORROSIVE TO ALL BODY TISSUES. CADMIUM AND
NICKEL, THE ELECTRODE MATERIALS ARE CARCINOGENIC.
Explanation of Carcinogenicity:CONTAINS C [7440-43-9] WHICH IS
LISTED BY NTP AND IARC AND REGULATED BY OSHA AS A CARCINOGEN.
Effects of Overexposure:IF BROKEN: CORROSIVE TO ALL BODY TISSUES.
Medical Cond Aggravated by Exposure:NOT KNOWN

First Aid

First Aid:GET MEDICAL ATTENTION IF SYMPTOMS PERSIST. SKIN:FLUSH WITH
PLENTY OF WATER. EYE:FLUSH WITH WATER FOR 15 MINUTES, HOLDING
EYELIDS OPEN. INHALED:REMOVE TO FRESH AIR. ORAL:DO NOT INDUCE
VOMITING. IF VOMI TING OCCURS SPONTANEOUSLY, KEEP HEAD BELOW HIPS
TO PREVENT ASPIRATION OF LIQUID INTO LUNGS. GET MEDICAL ATTENTION.

Fire Fighting

Flash Point:NOT RELEVANT
Extinguishing Media:WATER SPRAY, CARBON DIOXIDE, FOAM OR DRY CHEMICAL
FOR SURROUNDING FIRE. USE WATER SPRAY TO COOL FIRE EXPOSED
CONTAINERS.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING AND
NIOSH-APPROVED SELF-CONTAINED BREATHING APPARATUS WITH FULL
FACEPIECE OPERATED IN THE POSITIVE PRESSURE MODE.
Unusual Fire/Explosion Hazard:CADMIUM OXIDE FUMES, DUST,VAPORS

Accidental Release

Spill Release Procedures:WASH DOWN WITH WATER, NEUTRALIZE WITH CITRIC
ACID
Neutralizing Agent:CITRIC ACID

Handling

Handling and Storage Precautions:STORE IN COOL, DRY AREA. PROTECT FROM
PHYSICAL DAMAGE.
Other Precautions:WEAR GLOVES TO HANDLE LEAKING BATTERIES.

Exposure Controls

Respiratory Protection:NONE
Ventilation:NONE
Protective Gloves:RUBBER, IF HANDLING LEAKERS
Eye Protection:GOGGLES RECOMMENDED
Other Protective Equipment:RUBBER OR PLASTIC GARMENTS IF HEANDLING
LEKERS, EYE WASH STATION
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES.
Supplemental Safety and Health
THIS MSDS WAS GENERATED USING THE NI-CAD MSDS OF THIS MANUFACTURER FOR
NSN 6140-00-402-6350.

Chemical Properties

HCC:Z5
Melt/Freeze Pt:M.P/F.P Text:NOT KNOWN
Decomp Temp:Decomp Text:NOT KNOWN
Spec Gravity:NOT KNOWN
Evaporation Rate & Reference:NOT RELEVANT
Solubility in Water:NOT RELEVANT
Appearance and Odor:MANUFACTURED ARTICLE (BATTERY)

Stability

Stability Indicator/Materials to Avoid:YES
AVOID ACIDS
Stability Condition to Avoid:EXCESSIVE HEAT
Hazardous Decomposition Products:MAY FORM TOXIC FUMES.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE
AND FEDERAL REGULATIONS. DO NOT INCINERATE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.